Grade compatibility

Through ANALYSIS and TESTING

Emission and susceptibility

The growing integration of the electronic systems in nuclear and industrial demands to ensure compliance with the requirements of the electromagnetic compatibility (EMC), ensuring that the implementation of the new equipment does not affect other systems, and its operation is reliable in its electromagnetic environment real.

 

NUCLEONOVA provides rating services EMC of equipment according to the referential international nuclear and europeans, including the regulatory requirements, as well as reference guides in the sector as the Regulatory Guide 1.180 of the NRC, RCC-E, IEC/EN apply (e.g. IEC 61000) and specific requirements of the nuclear operators.

Due to the advancement of computers and the introduction of electronic systems, there is a new need to comply with the requirements of compatibility, being able to ensure that the installation of such equipment shall not affect third parties, as well as the new equipment to install, it will work properly under the electromagnetic conditions of the location.

It is for this reason that NUCLEONOVA offers its service Qualification of Equipment for requirements of Electromagnetic Compatibility according to specific regulations, such as the Regulatory Guide 1.180 of the NRC (Nuclear Regulatory Commision of USA).

Rating seismic

Verification of the reliability of components in case of seismic events

Through TESTING and CALCULATIONS

NUCLEONOVA performs ratings seismic equipment nuclear and industrial to verify its correct operation under conditions of vibration and during or after seismic events. We apply justification analytical, numerical modeling, and essays seismic, according to the referential nuclear europeans, French and international (IEC, IEEE, EPRI, KTA, among others), ensuring complete documentation, traceable, and conforms to the regulatory requirements, and licensing.

 

In certain applications it is required the verification of the correct functioning of the equipment under certain conditions of vibration, or during/after a seismic event, so it is necessary to perform a process of seismic qualification.

IEEE 344 “Seismic Qualification of Equipment for Nuclear Power Generating Stations”
IEEE 382 “Qualification of Safety-Related Actuators for Nuclear Power Generating Stations”
RG 1.100 “Seismic Qualification of Electric'an Mechanical Equipment for nuclear Power Plants”
RG 1.29 “Seismic Design Classification”
EPRI NP-7484 “Guideline for the Seismic Technical Evaluation of Replacement Items for NPP”
EPRI NP-6041-SLR1 “A Methodology for Assessment of Nuclear Power Plant Seismic Margin”
KTA 3504 “Electrical Drive Mechanisms of the Safety System in NPPs”
KTA 3505 “Type Testing of Measuring Sensors and Transducers of the Safety-Related Instrumentation and Control System”
IEC 60068-2 “Environmental testing – Vibration”
IEC 60980 “Recommended practices for seismic qualification”

Environmental rating

Verification of the reliability of equipment exposed to extreme environmental conditions

Through ANALYSIS and TESTING

In certain applications it is necessary to verify and justify the correct operation of the equipment under harsh environmental conditions (temperature, pressure, humidity, radiation, etc), as well as during or after events that significantly disrupt the normal operating conditions.

NUCLEONOVA offers services environmental rating of equipment, which include studies of shelf life, certification, under specific environmental conditions, aging tests and environmental rating according to IEEE and other reference applicable, ensuring the documentation and compliance required in environments nuclear and industrial.

In certain applications it is required the verification of the correct functioning of the equipment in certain environmental conditions, such as temperature, pressure, humidity, radiation, etc, or during/after an event fortuitous that modify a large extent these conditions of normal operation, so it is necessary to justify/document the ability of these teams under these conditions.

* Study of the useful life of equipment
* Certification of equipment under certain environmental conditions
* aging Tests
* environmental Rating according to IEEE or other

Dedication of components of Commercial Grade (CGID)

We carry out the activities necessary to ensure that Components of Commercial-Grade can be used in Safety-Related applications in Nuclear Facilities.

These Processes Dedication of Components of Commercial-Grade is done following the guidelines established by the Electrical Power Research Institute (EPRI) and ASME NQA-1, among others. In particular, EPRI NP-5652, EPRI NP-6404, ASME NQA-1 Subpart 2.14, 10CFR50 appendix B, 10CFR21, UNE 73.104, etc

Technical Evaluation

In defining the technical and quality requirements of the component, identifying the Critical Characteristics and Acceptance Criteria in function of the Safety Function.

Acceptance process

Through the verification and documentation of compliance with these requirements by using one or more of the methods of acceptance recognized (inspection, testing, analysis or audit of the supplier).

Qualified experts and tested methodologies

NUCLEONOVA account with highly qualified experts and tested methodologies, backed by its experience and evaluations of nuclear projects, ensuring processes of dedication robust, traceable and compliant.

Regulatory framework and reference implementation :

NucleoNova

Experience in rating and CGID

Lorem Ipsum

MAIN CUSTOMERS

Regulatory framework and reference implementation

Marco regulatorio y referenciales de aplicación Principales documentos de referencia

IEC/IEEE 60980-344 o IEEE 344

Nuclear facilities - Equipment important to safety - Seismic qualification
Seismic Qualification of Equipment for Nuclear Power Generating Stations

IEEE 382

Qualification of Safety-Related Actuators for Nuclear Power Generating Stations

RG 1.100 (US NRC)

Seismic Qualification of Electric and Mechanical Equipment for Nuclear Power Plants

RG 1.29 (US NRC)

Seismic Design Classification

RG 1.180 (US NRC)

EMC / EMI Testing

EPRI NP-7484

Guideline for the Seismic Technical Evaluation of Replacement Items for NPP

EPRI NP-6041-SLR1

A Methodology for Assessment of Nuclear Power Plant Seismic Margin

KTA 3504

Electrical Drive Mechanisms of the Safety System in NPPs

KTA 3505

Type Testing of Measuring Sensors and Transducers of the Safety-Related Instrumentation and Control System

IEC 60068-2

Environmental testing – Vibration

IEC 60980

Recommended practices for seismic qualification

Decreto INB del 7/02/2012 (Francia)

Règles générales relatives aux installations nucléaires de base

RCC-M

Règles de conception et de construction des matériels mécaniques des ilôts nucléaires REP

RCC-E

Règles de Conception et de Construction des Systèmes et Matériels Electriques et de Contrôle Commande

RCC-MRx

Règles de conception et de construction des matériels mécaniques des installations nucléaires hautes températures, expérimentales et de fusion

(NP-5652, NP-6404)

IAEA-TECDOC-2034

Suitability Evaluation of Commercial Grade Products for Use in Nuclear Power Plant Safety Systems

IAEA-NR-T-3.31

Challenges and approaches for Selecting, Assessing and Qualifying Commercial Industrial Digital Instrumentation and Control Equipment for Use in Nuclear Power Plant Applications

EPRI NP-5652 and TR-102260 Rev.1 (2014 Technical Report / 3002002982)

Plant Engineering: Guideline for the Acceptance of Commercial-Grade Items in Nuclear Safety-Related Applications

Foratom Volume 1 – Methodology, Volume 2 – User’s guide

FORATOM Quality Assurance Guideline for Procuring High-Quality Industrial Grade Items Aimed at supporting safety functions in nuclear facilities

Nucleonova Reverse Engineering & Dedication CGID_feder